Procedure to prepare the smart switch vPro for warranty shipping. Send only the complete electronic module; keep the glass faceplate and the metal frame.
Confirm the process beforehand with Smartify. Ensure a secure closing solution beforehand; if impossible, do not start the removal and request technical assistance.
How to request warranty
- Access My account → Purchases and Invoices → Return / Report Fault.
- If you don't have an account, you can create one with the same email used for the purchase.
- If the purchase does not appear, use the form at the end of that page to request access with your NIF.
Wait for instructions from Smartify before removing or sending the equipment.
2. Remove the faceplate and unscrew the frame
Remove the glass faceplate according to the model's instructions. Unscrew the metal frame from the wall box. Carefully bring the frame + module assembly forward, keeping it supported, without pulling the wires or separating the module from the frame yet.


3. Record, disconnect and isolate
Before handling the wires, check for the absence of voltage at the accessible terminals, according to the bipolar check in step 1. Before disconnecting any wire, photograph all connections and label each wire with the identification of its original terminal, for later connection to the same terminal. Do not deduce by color. Disconnect and isolate each end individually with an insulated connector suitable for the voltage and wire section, with no exposed copper and without joining different wires. Do not use only electrical tape.
4. Unclip the module from the frame
Only after disconnecting all wires and individually isolating all ends, unclip the electronic module from the metal frame, releasing only the intended clips, without forcing. Do not open the module housing. Keep the glass faceplate and the frame.

5. Screw the frame back on and close
Place the already isolated wires inside the box. Screw the metal frame back on and place the faceplate, leaving the box closed and with no accessible wires. If it is not possible to close it this way, use a suitable cover. Keep the circuit disconnected while the module is removed.
6. Pack and send
Pack only the complete electronic module, protected in a rigid box. Include the process reference and the description of the fault.